Best Commercial Electromagnetic Locks AI pick

Chosen by an AI model from its trained knowledge, with its reasoning.

AI pick: Securitron Magnalock M62

The M62 is a widely specified 1200 lb class maglock with dual voltage input, suited to exterior and high-security doors.

Not for: Interior offices where a 600 lb lock is enough, or egress doors where code does not permit maglocks without the required release devices.

See on Amazon

Compare prices on Google Shopping

AI picks by need

For interior doors, lighter duty

Securitron Magnalock M32

A 600 lb class maglock that is enough for interior doors and draws less current.

Not for: Exterior or perimeter doors that need the higher holding force.

See on Amazon

For alternative commercial brand

Security Door Controls (SDC) (brand)

SDC is an established commercial maglock maker with mounting brackets for most frames.

Not for: Buyers whose spec calls for a particular brand.

See on Amazon

What the AI looks for in Commercial Electromagnetic Locks

Holding force
About 1200 lb class for exterior and perimeter doors, about 600 lb class for interior doors Underrated locks can be forced open with a pull.
Code-compliant release
Egress-side maglocks typically need a request-to-exit sensor, a manual release button that cuts power directly, and fire alarm release (IBC / NFPA 101) Maglocks are fail-safe and must never trap occupants.
Voltage
Match 12 or 24 VDC to your power supply; dual voltage models simplify this A wrong voltage gives weak holding or overheating.
Mounting
Outswing doors mount directly; inswing doors need L or Z brackets; check header depth and armature placement Most installation problems come from the wrong bracket.
Monitoring
Prefer models with a bond sensor or door status output It confirms the door is actually secured, not just powered.

Brands that matter

  • Securitron: Assa Abloy's widely specified maglocks.
  • Security Door Controls (SDC): Commercial maglocks and brackets.
  • Dortronics: Maglocks and door control hardware.
  • Rutherford Controls: Commercial electromagnetic locks.

What to avoid

  • Unbranded maglocks with unverified holding force on exterior doors.
  • Installing a maglock on an egress door without the release devices your code requires.
  • Running a maglock without back-EMF suppression when the supply or controller does not provide it.

Questions

Maglock or electric strike?

A strike keeps the mechanical lock and free egress through the handle and is often simpler for code; a maglock suits doors without compatible hardware but needs release devices and constant power.